Emc Isilon Pdf4/27/2021
Note If you are installing a node that contains SEDs (self-encrypting drives), the node will format the drives at this time.You can follow the procedure in this guide to: Install several nodes to create a new cluster.The sliding rail kit is compatible with rack cabinets with the following hole types: 38 inch square holes 932 inch round holes 10-32, 12-24, M5X.8, or M6X1 pre-threaded holes.Shoulder Alignment Pin for Pre- Hole Racks Threaded Racks Procedure 1.
Confirm the type of rack you are installing the rails in and replace the alignment pins if necessary. If you are installing the rails in a rack with 38 inch square-holes or 932 inch round-holes, you do not need to adjust the alignment pins. Outer slide rail 2. CAUTION To minimize the chance of personal injury or equipment damage, and to ensure proper slide rail installation, it is recommended that two people lift and move the node. Chassis Retaining Screw Results DANGER Do not continue with this procedure until you have confirmed the following: 1. Both rails are secured to the rack and all mounting screws are in place and tightened. The inner slide rails attached to the node are inserted correctly, and firmly secured, in the intermediate slide rails that are attached to the rack. Locking handle 2. Drive bay 2. Hold the drive in place and gently push the drive locking handle down against the end of the drive to secure the drive in the drive bay. Repeat the previous steps until the front bays of the node are full. Note Drives that are not fully seated will not be recognized when the node starts, and a red light will appear below the drive. Rear EMI shield 5. Insert and lock drives into the back bays until they are full. Rear EMI shield 2. Locking handle 3. Drive bay 6. Replace the rear EMI shield. You can use the keypad and LCD to perform basic configuration tasks. Procedure 1. Install the front panel assembly by aligning the front panel with the front of the node and then pressing the front panel onto the node. LEDs Do not rely on LEDs to determine the health of a node or node component. If any hardware component is in an error state, identify and troubleshoot the error through OneFS events and alerts. If the network topology supports a second internal network, connect the int-b port to a separate network switch for the int-b network. Connect the external client network The ethernet cable connects the node to the clusters external network so the node can communicate with external clients. SmartLock compliance mode You can configure nodes to operate in SmartLock compliance mode. You should only choose to run your cluster in SmartLock compliance mode if your data environment must comply with SEC rule 17-a4(f). The wizard provides step-by-step guidance for configuring a new cluster or adding a new node to an existing cluster. Emc Isilon Serial Connection ToThe following procedure assumes that there is an open serial connection to a new node. Note You can type at most prompts to return to the previous step in the wizard. IP range The int-a network must be on a separate subnet from an int-bfailover network. Secure join A configured node in the existing cluster must invite a new unconfigured node to join the cluster.
0 Comments
Read More
Leave a Reply. |